1D / Stacked Symbology Qualification - Microscan MS-4 User Manual

Imager
Hide thumbs Also See for MS-4:
Table of Contents

Advertisement

1D / Stacked Symbology Qualification

Minimum Number of Bars
Definition:
Sets the minimum number of bars to qualify linear symbols.
Serial Cmd:
<K717,minimum number of
lines,start/stop status>
Default:
0
Options:
0 to 255 (0 is disabled)
Minimum Number of Qualified Scan Lines
Definition:
Sets the minimum number of scans that have the required number of
bars set in Minimum Number of Bars.
Important: This is a percentage value, from 0 to 100.
Serial Cmd:
<K717,minimum number of
lines,start/stop status>
Default:
Disabled
Options:
Any number from
Start/Stop Status
Definition:
When enabled, both Start and Stop characters need to be present to
qualify as a decodable symbol. In the case of PDF417, only a Stop needs
to be present.
Serial Cmd:
<K717,minimum number of bars,minimum number of qualified scan
lines,start/stop
Default:
Disabled
Options:
0 = Disabled
MS-4 Imager User's Manual
bars,minimum number of qualified scan
bars,minimum number of qualified scan
0
to 100 (0 disables this feature).
status>
1 = Enabled
I/O Parameters