ISO/IEC 16022 Symbol Quality Output 1
Output on Axial Non-Uniformity
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 to an active state when Axial Non-Uniformity
Threshold is met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth
uniformity threshold,output on UEC,UEC threshold>
Default:
Disabled
Options:
0 = Disabled
Output on Unused Error Correction
Usage:
Lets the user know if symbol quality is less than acceptable.
Definition:
If enabled, toggles Output 1 to an active state when UEC Threshold is met.
Serial Cmd:
<K800,output on symbol contrast,symbol contrast threshold,output on print
growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity
Default:
Disabled
Options:
0 = Disabled
Symbol Contrast Threshold
Usage:
Lets the user set the acceptable level of symbol quality.
Definition:
Conforms to ISO/IEC 16022 symbol quality grading (A,B,C,D).
Serial Cmd:
<K800,output on symbol
growth,print growth threshold,output on axial non-uniformity,axial non-
uniformity threshold,output on UEC,UEC threshold>
Default:
Grade C
Options:
0 = Grade A
3 = Grade D
7-36
threshold,output on axial
1 = Enabled
threshold,output on
1 = Enabled
contrast,symbol contrast
1 = Grade B
non-uniformity,axial non-
UEC,UEC threshold>
threshold,output on print
2 = Grade C
MS-4 Imager User's Manual