Number of Captures
Usage:
Used to increase the opportunities for good reads and to "extend" the field
of view in dynamic applications.
Definition:
Sets the total number of captures that are processed during a read cycle in
Rapid Capture Mode when Switching Mode is set to Number of Captures.
Serial Cmd:
<K241,capture
Default:
1
Options:
1
to 32
Note: The range of maximum number of captures is dynamic. This range is dependent
on the maximum image size in the system. A full-size image (640 x 480) reduces the
maximum number of images to 6. The smaller the image size, the greater the maximum
number of captures. Once the image size is reduced to small enough dimensions, the
maximum number of captures will be capped at 32.
If a user enters a maximum capture value greater than that allowed, the value will be
limited to the number of system images. This command also affects the number of
stored images allowed in the system. If the maximum number of captures is selected,
the number of stored images allowed will be 0.
Rapid Capture Mode
Definition:
In Rapid Capture Mode, one or multiple captures (as many as 32) can be
taken at an interval specified by the time-between-captures parameter. In
this mode, the only limiting time factor is integration and transfer timing.
Serial Cmd:
<K241,capture mode,number of
Default:
Timed Capture
Options:
0 = Timed Capture
MS-4 Imager User's Manual
mode,number of
captures,rapid capture mode>
captures,rapid capture
1 = Triggered Capture
Read Cycle
mode>
5-17