EZ Button Modes
Target System
Turns on the target pattern whenever the associated button position is selected. To disable,
quickly press and release the EZ button.
Note: This mode is the only one that does not require that the button be released before
taking effect. Thus, as soon as the Imager beeps the appropriate number of times for the
position, it will take effect. If it is necessary to have the target system on before another
operation such as calibration or read rate is performed, ensure that the target system
mode is assigned a lower position so that it will be activated first.
Bar Code Configuration
Enables bar code configuration mode whenever the associated button position is
selected. When enabled, the Imager can accept configuration commands from bar codes
without first reading a special, coded Data Matrix ISO/IEC 16022 symbol. To disable,
quickly press and release the EZ button.

EZ Button Operation

To execute EZ button commands,
Single Beep (Position #1)
Hold down button until a single beep is heard (and the 20% LED illuminates).
Two Beeps (Position #2)
Hold down button until two quick beeps are heard (and the 20% and 40% LEDs illumi-
nate.)
Three Beeps (Position #3)
Hold down button until three quick beeps are heard (and the 20%, 40%, and 60% LEDs
illuminate).
Four Beeps (Position #4)
Hold down button until four quick beeps are heard (and the 20%, 40%, 60%, and 80%
LEDs illuminate).