Linear Symbols:
1. Failed user defined minimum number of bars.
2. Failed to decode start/stop character (doesn't apply to UPC, GS1 DataBar, or
MicroPDF417).
3. Failed user defined minimum number of scan lines that qualify for the minimum
number of bars.
4. Failed to decode.
5. Failed to decode UPC supplemental.
No Read Message
Definition:
Any combination of ASCII characters can be defined as the No Read
message.
Serial Cmd:
<K714,No Read message
Default:
No Read
Options:
A string of up to 64 ASCII characters.
Note: No Read Message will only be transmitted if Symbol Data Output is set to Match,
Mismatch, or Good Read.
No Read Message can be set to any ASCII character.
Important: The ASCII characters <, >, and , can only be entered as hex pairs:
For <:
<K714h,,3C>
For >:
<K714h,,3E>
,
For
:
<K714h,,2C>
See
ASCII Character Entry Modifier
enter ASCII characters as hex values.
MS-4 Imager User's Manual
status,No Read
message>