Interleaved 2 of 5
Guard Bar Status (Interleaved 2 of 5)
Note: Whenever Guard Bar is enabled, the presence of guard bars (also called "bearer
bars") is required for decoding to take place.
Usage:
Useful when I-2/5 multisymbols are enabled to prevent false data output.
This typically occurs with highly tilted or skewed symbols.
Definition:
A guard bar is a heavy bar, at least twice the width of the wide bar, surrounding
the printed I-2/5 symbol and helping to prevent false reads.
Serial Cmd:
<K472,status,check digit status,check digit output,symbol length #1,symbol
length
Default:
Disabled
Options:
0 = Disabled
Range Mode Status (Interleaved 2 of 5)
Usage:
Useful in applications where I 2/5 symbols of a specific length are required.
Definition:
When Range Mode is disabled, the Imager checks the value of the symbol
length against the values set in Symbol Length # 1 and Symbol Length #
2. If the symbol length does not match either of the preset values, then it is
rejected as invalid.
When Range Mode is enabled, Symbol Length # 1 and Symbol Length #
2 are combined to form a range of valid symbol lengths. Any symbol length
that does not fall into this range is rejected as an invalid symbol. Either of
the preset symbol length values in the Symbol Length # 1 and Symbol
Length # 2 fields can form the start or end of the range.
Serial Cmd:
<K472,status,check digit status,check digit output,symbol length #1,symbol
length #2,guard bar
Default:
Disabled
Options:
0 = Disabled
6-16
#2,guard bar
status,range mode status>
1 = Enabled
status,range mode
1 = Enabled
status>