Length
Definition:
Specifies the length of the decoded symbol allowed to occupy this location
in multi-symbol output.
Note: To filter or order a symbol, the symbol must meet all requirements of
the selected filter index.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data,
unused,database index>
Default:
0
Options:
0 to 64
Wildcard
Definition:
This is the character to be used in the data output field when performing a data
filter comparison. The wildcard character represents the end of matching, and
allows for variable lengths of symbol output.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data,
unused,database index>
*
Default:
"
" = 2A (hex)
Options:
Any ASCII input in the form of a pair of hex characters.
Example:
2A =
00 = disabled
See
ASCII Character Entry Modifier
enter ASCII characters as hex values.
Placeholder
Definition:
The placeholder character requires a character to be present, but does not
compare the data value.
Serial Cmd:
<K744,filter number,symbology type,length,wildcard,placeholder,data,
unused,database index>
Default:
"
?
Options:
Any ASCII input in the form of a pair of hex characters.
Example:
3F = ?
00 = disabled
See
ASCII Character Entry Modifier
enter ASCII characters as hex values.
MS-4 Imager User's Manual
*
on page 3-32 for a detailed explanation of how to
" = 3F (hex)
on page 3-32 for a detailed explanation of how to