Epson MR Series Technical Reference Manual page 108

Table of Contents

Advertisement

is overwritten by new data before it is processed sometimes occurs. When setting the FIFO,
the overrun error can be avoided using the inner cache. This item is set to 8 generally, so
there is no need to change it.
❏ [Check Port]
This displays the time interval (the second) for checking the COM Port condition for
connected the touch panel. This item cannot be set here.
Settings
The following screen is displayed if the Settings tab is clicked.
❏ [General settings for]
Select the touch panel device name to set. Generally, "Device 1" is selected.
❏ [Click time]
The click time is the timer set in 55 ms units. The default setting is 1.
If the screen is touched and the finger does not move within the specified time, a click is
executed.
❏ [Tap time]
The Tap time is the timer set in 55 ms units. The default setting is 9. If the button mode is set
to the "Tap Mode," when the finger is left in one place for the specified time, it is registered
as a double click.
❏ [Lift off time]
The Lift off time is set in 55 ms units. The default setting is 2. If Use liftoff packet is selected,
the program will ignore any lifting of the finger shorter than the time specified.
❏ [Stabilization]
This ignores the data when the change of the touch position data is smaller than the set
value. The default setting is 0. For example, if this is set to 20, no change of position is
registered if the change of the touch position is less than 20.
4-58 OS and Drivers
Rev. I

Advertisement

Table of Contents
loading

This manual is also suitable for:

Im-800Dm-m820

Table of Contents