AMX Enova DGX 8 Instruction Manual page 83

Enova dgx digital media switchers
Hide thumbs Also See for Enova DGX 8:
Table of Contents

Advertisement

Enova DGX DXLink Twisted Pair Board Specifications (continued)
Audio Format Support
Audio Resolution
Audio Sample Rate
Local Audio Support
EDID Support
HDCP Support
CEC Support
ICSP, TCP/IP, USB, IR, and
Control Management
DXLink Power
Input Board Propagation
Delay
Output Board Propagation
Delay
Connectors
Twisted Pair Cable Type
Twisted Pair Cable Length
* Dolby Digital and DTS support up to 48 kHz, 5.1 channels.
** For more details and helpful cabling information, reference the white paper titled "Cabling for Success with DXLink"
available at www.amx.com or contact your AMX representative.
*** "Common building" is defined as: Where the walls of the structure(s) are physically connected and the structure(s)
share a single ground reference.
AMX reserves the right to modify its products and their specifications without notice.
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
Dolby TrueHD, Dolby Digital*, DTS-HD Master Audio, DTS*, 2 CH L-PCM, 6 CH L-PCM,
8 CH L-PCM
16 bit to 24 bit
32 kHz, 44.1 kHz, 48 kHz, 96 kHz, 192 kHz
Yes, insertion and/or extraction of 2 CH L-PCM selectable by channel
• EDID provided by Enova DGX Digital Media Switcher to the DXLink HDMI TX
• EDID provided by Enova DGX Digital Media Switcher to the digital (HDMI) input
on the DXLink Multi-Format TX
• EDID is user re-programmable
Yes, full matrix HDCP support (includes any input to any or all outputs, except for
SC Optical inputs and outputs)
• Key Management System
®
• AMX HDCP InstaGate Pro
• Key support up to 16 destinations per output, independent of source device
None
Control Distribution is managed by the Enova DGX Digital Media Switcher on-board
NetLinx Master and Ethernet Switch
DXLink Transmitters and Receivers can have power supplied over twisted pair cable
when connected to a DXLink Input or Output Board on the Enova DGX Digital Media
Switcher
5 s
5 s
4 RJ-45 ports
Shielded Cat6, Cat6A, Cat7**
Up to 328 ft. (100 m)**
Important: DXLink twisted par cable runs for DXLink equipment shall only be run within
a common building.***
Enova DGX DXLink™ Twisted Pair Boards
Technology
83

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enova dgx 32

Table of Contents