AMX Enova DGX 8 Instruction Manual page 142

Enova dgx digital media switchers
Hide thumbs Also See for Enova DGX 8:
Table of Contents

Advertisement

4. Select the "Master" KIT file from the Files list.
FIG. 85
Send To NetLinx Device dialog showing KIT file for the integrated Master selected


5. Check the number for the device to be upgraded in the Device text box.


6. Review the File, Connection, Address, and Target Device information before you send the KIT file.
7. Important – Select the Reboot Device check box. This ensures that the system reboots when the download of
the KIT files is complete.
Master Upgrade
8. Click Send. A status bar is provided under Progress. NetLinx Studio transfers the files to the integrated
Master on the Enova DGX Switcher and then tells the system to reboot.

Enova DGX Switcher Upgrade (Offline Upgrade)
Important: Upgrading the switcher's firmware can take a considerable amount of time depending on the
components being upgraded in the system. If you are unsure of the progress, the upgrade status is displayed
in the WebConsole and updates periodically. In the WebConsole after the IP address, enter /web/upgrade/
systemUpgradeStatus.xml (for example, http://192.168.44.60/web/upgrade/systemUpgradeStatus.xml).
Since the switcher is offline, the direct path must be used.
9. Select the "Enova DGX" KIT file from the files list. Click Send. A status bar is provided under Progress.
NetLinx Studio transfers the files to the Enova DGX Switcher and then tells the system to restart, at which
time the upgrade process begins.







* During normal operation a blinking red Status LED is cause for concern (indicates the system is in IOS mode).
However, during firmware upgrade the system may be in IOS mode for a period of time.
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
The selected directory path is displayed in the Send to NetLinx Device dialog (Location field).
Assuming the specified target directory contains one or more KIT files, the KIT files in the selected directory
are displayed in the Files list along with the last modified date and time.
The device number assigned to the integrated Master is 0 (zero).
The switcher's default device number is 5002. (If the device number has been changed, use the OnLine Tree
to determine it.)
During the Master's upgrade process, some of the LEDs on the CPU go through an extended series of
blinking. When finished, all LEDs return to their normal state.
During the switcher's upgrade process:
The Enova DGX Switcher stays offline (does not display in OnLine Tree).
Some of the LEDs on the CPU blink* depending on the components being upgraded.
Power cycles will not abort the upgrade; let it run until completion.
Once the upgrade is complete (to determine when, see "Important" above Step 9):
The LEDs return to normal.
The Enova DGX Switcher comes back online (displays in OnLine Tree).
Firmware Upgrade & Info for Network Admin
Directory path
KIT files
I
mportant: If both require updates, always upgrade
in the following order:
Device 0 – NetLinx integrated Master
Device 5002 (default) – Enova DGX
142

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enova dgx 32

Table of Contents