The instructions for options A, B, and C assume that the previous instructions for reading an EDID have been
completed and the DGX Configuration Software is open to the Scaler Override view.
(A) To set an EDID timing that was read from the detected device:
FIG. 91
Scaler Override view with EDID selected
1. Under Resolution Source, click EDID.
2. Under EDID from Detected Device – From the Available Display Modes drop-down list, select the desired
resolution (only resolutions supported by the detected device are included).
3. In the device tree on the left, select an output to send the resolution information to that output. Multiple
outputs may be selected.
4. Click Apply to transmit the selected information to the output(s). This action is temporary until settings are
stored on the connector(s) in Step 6. Otherwise, the settings last only until power is cycled. The display
re-syncs with the input(s).
5. Verify that the display is satisfactory before proceeding.
6. Click Save to store the currently displayed settings to the connector(s) and persist them in memory.
(If the settings have been changed since clicking Apply, the newest settings will be saved.)
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
Appendix A – DGX Configuration Software
EDID selected
Device tree with Outputs
159