AMX Enova DGX 8 Instruction Manual page 184

Enova dgx digital media switchers
Hide thumbs Also See for Enova DGX 8:
Table of Contents

Advertisement

Categories Pane
The Categories pane is the left-most pane in the Main Screen and presents the highest-level information about the
overall system status. The Categories pane has two tabs: Diagnostics and System.
When maximum and minimum levels of operation for various components in the system are exceeded,
APDiagnostics flags that information as warnings or errors (depending on the data received) by changing the color
of the Categories buttons in the Categories pane to yellow for warning or red for error and by displaying the
information as Warnings or Errors in the Event Status Notebook.
Diagnostics Tab
System Tab
Instruction Manual – Enova DGX 8/16/32 Digital Media Switchers
The two buttons on the Diagnostics tab (Temperature and Power System) will turn
green, yellow, or red indicating Good, Warning, or Error state, respectively. A yellow
for warning or red for error button indicates that the maximum or minimum levels of
functioning for various components in the system has been exceeded. This allows you
to "drill down" into that particular system for more detailed information about the
state of its lowest-level constituents.
To display diagnostic information for Temperature and Power System
groups:
1. In the Categories pane, select the Diagnostics tab.
2. Click either the Temperature or Power System button. Visual, Plot, and Details
buttons display in the Information pane (see page 185).
The six buttons on the System tab offer general information for the following:
Enclosure Info

VM Configurations

Hardware Boards

Power Supply Info

Fan Status*

Signal Sense (for inputs and outputs)

To display general information for a particular component:
1. In the Categories pane, select the System tab.
2. Click one of the buttons on the System tab.
The details display in the Information pane (see page 185).
* A fan should be replaced if the speed drops significantly lower than its setting value,
indicating that it will eventually fail. If a fan has failed completely, its speed will be
reported as 0 RPM.
Appendix C – APDiagnostics
184

Advertisement

Table of Contents
loading

This manual is also suitable for:

Enova dgx 32

Table of Contents