Installing a USB embedded hypervisor flash device

Use this information for instructions on how to install a USB hypervisor flash
device.
About this task
To install a hypervisor flash device, complete the following steps:
Procedure
1. Read the safety information and installation guidelines, see "Safety" on page vii
2. Turn off the server (see "Turning off the server" on page 41) and all attached
3. Remove the standard I/O book (see "Removing the standard I/O book" on
4. Locate the USB flash device (hypervisor) connector on the standard I/O book
5. Make sure that the lockbar on the USB (hypervisor) connector is in the unlock
6. Align the USB flash device with the connector on the standard I/O book board
7. Slide the lockbar up to the locked position until the lockbar is seated firmly.
114
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
and "Installation guidelines" on page 45.
peripheral devices. Disconnect all power cords; then, disconnect all external
cables from the server.
page 221).
board (see "Standard I/O book" on page 32 for the location of the connector).
position (down).
and push it into the connector until it is firmly seated.