80010204-1d03ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of Fan 3A or Fan 3B has gone low.
May also be shown as 800102041d03ffff or 0x800102041d03ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related Links:
v
"Removing a hot-swap fan assembly" on page 251
80010204-1d04ffff
Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.
Explanation: IMM has detected the speed of Fan 4A or Fan 4B has gone low.
May also be shown as 800102041d04ffff or 0x800102041d04ffff
Severity: Error
Alert Category: Critical - Fan Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0480
SNMP Trap ID: 11
Automatically notify Support: No
User response:
1. Reseat the failing fan indicated by the lit LED on the fan.
2. Replace Fan.
Related Links:
v
"Removing a hot-swap fan assembly" on page 251
80010204-1d03ffff • 80010204-1d04ffff
Appendix B. Integrated management module II (IMM2) error messages
531