80070319-2201ffff
Sensor S3 Resume Fail has transitioned to non-recoverable from a less severe state.
Explanation: The S3 Resume Fail sesor has transitioned to non-recoverable from less severe.
May also be shown as 800703192201ffff or 0x800703192201ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0524
SNMP Trap ID: 50
Automatically notify Support: No
User response: This is a UEFI detected event. The UEFI diagnostic code for this event can be found in the logged
IMM message text. Please refer to the UEFI diagnostic code in the "UEFI diagnostic code" section of the Information
Center for the appropriate user response.
Related Links:
"Finding the UEFI (POST) error code" on page 1666
v
80070603-1301ffff
Sensor [SensorElementName] has transitioned to non-recoverable.
Explanation: IMM has detected Voltage Regulator Error.
May also be shown as 800706031301ffff or 0x800706031301ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: yes
CIM Information: Prefix: PLAT and ID: 0530
SNMP Trap ID: 4
Automatically notify Support: no
User response:
v Compute Book 1 VRD: Indicates a problem with either the voltage regulator for CPU1 or microprocessor 1 itself
v Compute Book 2 VRD: Indicates a problem with either the voltage regulator for CPU2 or microprocessor 2 itself
v Compute Book 3 VRD: Indicates a problem with either the voltage regulator for CPU3 or microprocessor 3 itself
v Compute Book 4 VRD: Indicates a problem with either the voltage regulator for CPU4 or microprocessor 4 itself
v Planar VRD: Indicates a problem with a voltage regulator for the primary system board
v I/O Book 1 VRD: Indicates a problem with a voltage regulator for the IO Module
v I/O Book 2 VRD: Indicates a problem with a voltage regulator for the IO Module
v Storage Book VRD: Indicates a problem with a voltage regulator for the Storage Book Board
v Check the IMM Web event log. This event may be a symptom of an earlier error.
v Depending on the error perform the following steps.
For a CPU BOOK 1 VRD, CPU Book 2 VRD, CPU Book 3 VRD, or CPU Book 4 VRD error:
v Check the IBM support site for service bulletins or firmware updates that apply to this microprocessor error.
v Replace affected Compute Book.
For a Planar VRD error:
v Replace primary system board.
For a IO Book VRD error:
v Replace IO Book board.
80070319-2201ffff • 80070603-1301ffff
Appendix B. Integrated management module II (IMM2) error messages
599