IBM System x3850 X6 Installation And Service Manual page 651

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

806f0021-0b04ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 4.
May also be shown as 806f00210b04ffff or 0x806f00210b04ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: Replace PCIe card
Related Links:
"Installing an adapter" on page 84
v
"Removing the half-length I/O book" on page 226
v
"Removing the full-length I/O book" on page 228
v
806f0021-0b05ffff
Fault in slot [PhysicalConnectorSystemElementName] on system
[ComputerSystemElementName].
Explanation: IMM has detected a Fault in PCIe slot 5.
May also be shown as 806f00210b05ffff or 0x806f00210b05ffff
Severity: Error
Alert Category: Critical - Other
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0330
SNMP Trap ID: 50
Automatically notify Support: Yes
User response: Replace PCIe card
Related Links:
"Installing an adapter" on page 84
v
"Removing the half-length I/O book" on page 226
v
"Removing the full-length I/O book" on page 228
v
806f0021-0b04ffff • 806f0021-0b05ffff
Appendix B. Integrated management module II (IMM2) error messages
633

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x6

Table of Contents