IBM System x3850 X6 Installation And Service Manual page 662

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

806f0108-0a01ffff • 806f0108-0a02ffff
806f0108-0a01ffff
[PowerSupplyElementName] has Failed.
Explanation: IMM has detected a Fault on Power Supply 1.
May also be shown as 806f01080a01ffff or 0x806f01080a01ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
1. Check the log for additional Power Supply Failure.
2. Replace the Power Supply, if needed
Related Links:
v
"Solving power problems" on page 197
v
"Installing power supplies" on page 104
"Removing a 1400-watt or 900-watt hot-swap power supply" on page 247
v
"Removing a 750-watt -48 volt to -60 volt dc power supply" on page 287
v
"Replacing a 1400-watt or 900-watt hot-swap power supply" on page 248
v
"Replacing a 750-watt -48 volt to -60 volt dc power supply" on page 289
v
806f0108-0a02ffff
[PowerSupplyElementName] has Failed.
Explanation: IMM has detected a Fault on Power Supply 2.
May also be shown as 806f01080a02ffff or 0x806f01080a02ffff
Severity: Error
Alert Category: Critical - Power
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0086
SNMP Trap ID: 4
Automatically notify Support: Yes
User response:
1. Check the log for additional Power Supply Failure.
2. Replace the Power Supply, if needed
Related Links:
"Solving power problems" on page 197
v
"Installing power supplies" on page 104
v
"Removing a 1400-watt or 900-watt hot-swap power supply" on page 247
v
"Removing a 750-watt -48 volt to -60 volt dc power supply" on page 287
v
"Replacing a 1400-watt or 900-watt hot-swap power supply" on page 248
v
"Replacing a 750-watt -48 volt to -60 volt dc power supply" on page 289
v
644
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x6

Table of Contents