Table 38. Symptoms and user actions for connectivity problems (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 5, "Parts listing, System x3850 X6 and x3950 X6 Types 3837 and 3839," on page 205 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by (Trained service technician only), that step must be performed only by a Trained
service technician.
Symptom
The server cannot log into the
IMM.
The server cannot ping the
IMM on the management
network.

General problems

Use this information to solve general problems.
Table 39. Symptoms and user actions for general problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is
solved.
v See Chapter 5, "Parts listing, System x3850 X6 and x3950 X6 Types 3837 and 3839," on page 205 to determine
which components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by (Trained service technician only), that step must be performed only by a Trained
service technician.
Symptom
An LED is not working, or a
similar problem has occurred.
180
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Action
1. Verify that the server has DC power.
2. Make sure that you are using the correct log-in information. The fields are case
sensitive.
3. Check with the system administrator for the correct login parameters and if
parameters can log-in to the IMM, then do the following:
a. If the IMM is proven accessible (by system administrator), verify the login
information.
b. If the IMM is not accessible by system administrator, reset the IMM to
defaults through the Setup utility.
c. Retry the login. If IMM is still not accessible, replace the standard I/O book
(see"Removing the standard I/O book" on page 221 and "Replacing the
standard I/O book" on page 222).
1. Verify that the server has DC power.
2. Make sure that the server IMM has acquired an IP address in the Setup utility.
Note: If the IMM recently lost connection to the DCHP server, you must reset
the IMM so that a new IP address can be acquired.
3. Check the IBM Support web site for any firmware updates that might apply to
this problem (see http://www.ibm.com/supportportal/). Read the release
notes for the firmware update to determine the issues that the update
addresses.
Action
If the part is a CRU, replace it. If the part is a FRU, the part must be replaced by a
trained service technician (see Chapter 6, "Removing and replacing components,"
on page 217 to determine whether the part is a CRU or a FRU).