either of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may contain
a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)
3. Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.
4. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlash
DIMM is under warranty before replacement.
Related Links:
"Server features and specifications" on page 7
v
v
"Removing a DDR3 compute book" on page 283
"Replacing a DDR3 compute book" on page 284
v
"Removing the DDR3 compute book cover" on page 218
v
"Replacing the DDR3 compute book cover" on page 220
v
"Removing a memory module" on page 239
v
"Replacing a memory module" on page 240
v
"Flash DIMMs" on page 51
v
806f020d-2b810811
Failure Predicted on [NumericSensorElementName] for array
[ComputerSystemElementName].
Explanation: The eXFlash Proxy Service reported a failure predicted (PFA) on the eXFlash DIMM 17 in Compute
Book 1.
May also be shown as 806f020d2b810811 or 0x806f020d2b810811
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0168
SNMP Trap ID: 27
Automatically notify Support: Yes
User response: At the next maintenance opportunity:
1. Verify that the most recent eXFlash DIMM firmware and eXFlash IPMI Proxy Service are installed.
2. If the node has recently been installed, moved, serviced, or upgraded, verify that the eXFlash DIMM is properly
seated and visually verify that there is no foreign material in any DIMM connector on that memory channel. If
either of these conditions is found, correct and retry with the same eXFlash DIMM. (Note: Event Log may contain
a recent 00580A4 event denoting detected change in DIMM population that could be related to this problem.)
3. Check IBM support site for an applicable service bulletin or firmware update that applies to this eXFlash error.
4. If problem persists and there are no other eXFLash DIMMs with the same indication, confirm that the eXFlash
DIMM is under warranty before replacement.
Related Links:
"Server features and specifications" on page 7
v
"Removing a DDR3 compute book" on page 283
v
"Replacing a DDR3 compute book" on page 284
v
"Removing the DDR3 compute book cover" on page 218
v
"Replacing the DDR3 compute book cover" on page 220
v
"Removing a memory module" on page 239
v
"Replacing a memory module" on page 240
v
v
"Flash DIMMs" on page 51
Appendix B. Integrated management module II (IMM2) error messages