80010b01-2d01ffff • 80030006-2101ffff
80010b01-2d01ffff
Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has
asserted.
Explanation: The PCH temperature sensor has risen above its threshold. A hard shutdown has occurred.
May also be shown as 80010b012d01ffff or 0x80010b012d01ffff
Severity: Error
Alert Category: Critical - Temperature
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0498
SNMP Trap ID: 0
Automatically notify Support: No
User response:
1. Check the IMM event log for any fan or cooling related issues.
2. Make sure that the airflow at the front and rear of the server is not obstructed and that fillers are in place and
correctly installed.
3. Make sure that the room temperature is within operating specifications.
4. If this is the only temperature related event and the event persists, replace the system board (Trained Service
personnel only).
Related Links:
"Server features and specifications" on page 7
v
v
"Removing the standard I/O book" on page 221
80030006-2101ffff
Sensor [SensorElementName] has deasserted.
Explanation: Secure UEFI (Sig Verify Fail) update completed Successfully.
May also be shown as 800300062101ffff or 0x800300062101ffff
Severity: Info
Alert Category: System - Other
Serviceable: No
CIM Information: Prefix: PLAT and ID: 0509
SNMP Trap ID:
Automatically notify Support: No
User response: Information only; no action is required.
538
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide