IBM System x3850 X6 Installation And Service Manual page 559

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

80040104-1d02ffff
Sensor [SensorElementName] is asserting predictive failure.
Explanation: IMM predicted Fan 2 needs to be replaced to prevent a cooling failure.
May also be shown as 800401041d02ffff or 0x800401041d02ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0510
SNMP Trap ID: 27
Automatically notify Support: No
User response: Replace fan as soon as possible.
Related Links:
"Removing a hot-swap fan assembly" on page 251
v
"Replacing a hot-swap fan assembly" on page 252
v
80040104-1d03ffff
Sensor [SensorElementName] is asserting predictive failure.
Explanation: IMM predicted Fan 3 needs to be replaced to prevent a cooling failure.
May also be shown as 800401041d03ffff or 0x800401041d03ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0510
SNMP Trap ID: 27
Automatically notify Support: No
User response: Replace fan as soon as possible.
Related Links:
"Removing a hot-swap fan assembly" on page 251
v
"Replacing a hot-swap fan assembly" on page 252
v
80040104-1d04ffff
Sensor [SensorElementName] is asserting predictive failure.
Explanation: IMM predicted Fan 4 needs to be replaced to prevent a cooling failure.
May also be shown as 800401041d04ffff or 0x800401041d04ffff
Severity: Warning
Alert Category: System - Predicted Failure
Serviceable: Yes
CIM Information: Prefix: PLAT and ID: 0510
SNMP Trap ID: 27
Automatically notify Support: No
User response: Replace fan as soon as possible.
Related Links:
"Removing a hot-swap fan assembly" on page 251
v
"Replacing a hot-swap fan assembly" on page 252
v
80040104-1d02ffff • 80040104-1d04ffff
Appendix B. Integrated management module II (IMM2) error messages
541

Advertisement

Table of Contents
loading

This manual is also suitable for:

System x3950 x6

Table of Contents