Removing The Front Operator Panel Assembly - IBM System x3850 X6 Installation And Service Manual

Hide thumbs Also See for System x3850 X6:
Table of Contents

Advertisement

2. Install the adapters (see "Installing an adapter" on page 84).
3. Connect the cables to the adapters.
4. Connect the cables to the board assembly.
5. Close the adapter retention lever.
6. Align the storage book with the I/O bay on the server and slide it into the
7. Rotate the cam handle on the storage book all the way up and push it into the
8. Reconnect the power cord and any cables that you removed.
9. Turn on the peripheral devices and the server.

Removing the front operator panel assembly

Use this information for instructions on how to remove the front operator panel.
About this task
To remove the front operator panel, complete the following steps.
Procedure
1. Read the safety information and installation guidelines, see "Safety" on page vii
2. Turn off the server (see "Turning off the server" on page 41) and all attached
3. Remove the storage book from the server (see "Removing the storage book" on
4. Disconnect the front operator panel cables from the storage book board and
270
System x3850 X6 and x3950 X6 Types 3837 and 3839: Installation and Service Guide
Storage book
board assembly
server.
server until it locks in place.
and "Installation guidelines" on page 45.
peripheral devices. Disconnect all power cords; then, disconnect all external
cables as necessary to replace the device.
page 266).
from the rear air baffle.
Note: You might need to use a small flat-blade screwdriver to get under the lip
of the plug on the cable (the thermistor end of the cable) to remove the plug
from the air baffle and set it aside to install on the new assembly.