8.19 Register Solenoid

(1) Remove the bind B M3x10 Taptite screw.
(2) Remove the Register solenoid and the Solenoid release spring.
Register solenoid lever
8.20 Ejector Solenoid
(1) Remove the bind B M3x10 Taptite screw.
(2) Remove the Ejector solenoid and the Solenoid release spring.
Frame L
Solenoid release spring
Fig. 5-63
Solenoid release spring
Fig. 5-64
5-52
Taptite, bind B M3x10
Register solenoid
Frame L
aptite, bind B M3x10
Ejector solenoid
Ejector solenoid lever