2. IF YOU REPLACE THE PERIODICAL
MAINTENANCE PARTS
When replacing the periodical maintenance parts, clear each counters in following
procedures.
After clearing the counter, REPLACE COUNT will be counted up automatically when
prescribed numbers of prints are completed.
■ What you should prepare
(1) Computer (Windows
(2) bizhub 20P
(3) USB cable (one piece)
(4) PJL file for each periodical maintenance parts
(5) BrUsbsn.exe file
Copy it into the "bizhub" folder that has been created in the C drive. Extract the copied
file and run the BrUsbsn.exe file by double-clicking.
<Procedures>
CAUTION :
• Make sure that the printer driver for bizhub 20P is installed to the computer.
(1) Connect the computer to the printer with the USB cable.
(2) Double-click the BrUsbsn.exe file which has been copied in the "bizhub" folder to start.
(3) On the model menu, click Printer 2.
(4) In port on the BrUsbsn screen, select the port number assigned to the printer.
(5) Click-hold on the corresponded PJL file and drag and drop it on "BrUsbsn.exe" screen.
(6) The counter value will be cleared.
<List of PJL file for counter resetting>
FUSERRESET.PJL: Fuser Unit
LASERRESET.PJL: Laser Unit
PFKIT1RESET.PJL: PF kit for Tray 1
PFKIT2RESET.PJL: PF kit for Tray 2
PFKIT3RESET.PJL: PF kit for Tray 3
PFKITMPRESET.PJL: PF kit for MP
®