■ Electrodes location of the toner/drum unit
(3) Developer roller
■ Electrodes location of the machine
<How to clean the electrodes>
Turn off the power switch. Unplug the machine from the AC power outlet, and leave the machine
for a few minutes. Then, wipe the electrodes above carefully with a dry lint-free cloth. Be
careful not to change the shapes of the electrodes.
Toner/Drum Unit
Fig. 3-2
Grid
Cleaner
Fig. 3-3
3-16
(2) Charge
(4) Grid
(6) Cleaner
(1) Exposure drum
(5) Transfer roller
Charge
Developer roller
Exposure drum
Transfer roller