(3) Remove the bind B M4x12 Taptite screw, and then remove the High-voltage PS PCB
ASSY.
(4) Disconnect the three connectors from the High-voltage PS PCB ASSY.
Toner LED PCB connector
High-voltage PS PCB ASSY
Pins
Fig. 5-84
High-voltage PS PCB ASSY
MP PE sensor connector
PE EG sensor connector
Fig. 5-85
5-63
Taptite, bind B M4x12