(9) Turn the PE actuator MP to the direction of 9a and pull it up to remove.
MP feed frame
(10) Remove the bind B M3x8 Taptite screw, and then remove the MP PE sensor ASSY.
9b
Fig. 5-101
Taptite, bind B M3x8
MP feed frame
Fig. 5-102
5-72
PE actuator MP
9a
MP PE sensor ASSY