EPSON AcuLaser C4000/C4100/C3000
Table 8-1. List of Printer Messages
LED Message
(Display in test printing)
Calibrating Printer
Offline
*5
Cancel Print Job (by host)
uuuu Toner Low
Worn Photoconductor
Worn Fuser
Worn Transfer Unit
*5
Sleep
NonGenuine Toner
*5
Ready
(Printing)
(Communication to non-active I/F)
(executing of Job (possible to print))
The Printer Message list is described in the order or
C H E C K
P O I N T
descending priorities (the top item is the highest on
the list or priorities).
Refer to 3.3.3. "Service Call Error Messages"
*1:
*2: The relevant values among the Values of Paper Source in the panel setting except
for Auto are displayed.
*3: The relevant values among the Values for Paper Size in the panel setting are
displayed.
*4: The relevant values among the Values for each paper feed Size in the Tray Menu in
the panel setting are displayed.
*5: The remaining amount of toner is displayed on the right side of panel in order of C,
M, Y and K from the left.
Refer to 1.14.2. "Display Elements Description"
*6:
AcuLaser C4100
*6
Category
Error Light
Status code
1010
Status
---
1014
Status
---
1001
Status
---
1003
Warning
---
2571
Warning
---
2571
Warning
---
2571
Warning
---
2571
Status
---
1007
Warning
---
2571
Status
---
1000
Status
---
1009
Status
---
1012
Status
---
1002
.

Panel Message For Troubleshooting

7.2.2 Details of Error Message and Treatment

Install uuuu TnrCart
Description
One of the C, M, Y, K toner cartridges is not installed.
The uuuu display corresponds to the C, M, Y, K toner cartridges,
and indicates the cartridge that is not installed.
When protect tape is removed with installing bran-new toner
cartridge, this error occurs.
Treatment
By opening the top cover and installing the displayed toner
cartridge, the error is released.
When equipped a protect tape in the toner cartridge, remove the
toner cartridge from the printer, reinstall the toner cartridge and
remove the protect tape.
Install Fuser
Description
The Fuser Unit is not installed, or is not set correctry.Or the Fuser
Unit is broken.
Treatment
Turn the printer off, leave the printer for 30 minutes or more, open
the Cover B, push the left lever of the Cover D, open the Cover D
and install the Fuser Unit correctly. Close the Cover D and close the
Cover B at the end. When install Fuser message is displayed in
spite of above operation, the Fuser Unit is broken or is not
adaptable to this product.