EPSON AcuLaser C4000/C4100/C3000
4.2.4.13 COVER ASSY FRONT IN (PL1.2.10) Removal
1. Remove the FUSER ASSY. (See Section 4.2.12.1.)
2. Remove the COVER MSI. (See Section 4.2.4.11.)
3. Remove the TRAY ASSY MSI. (See Section 4.2.4.12.)
4. Remove the COVER ASSY FRONT HEAD. (See Section 4.2.4.2.)
5. Release the reinforced portion at the front of the LINK: L (PL1.2.5) from the
back panel of the COVER ASSY FRONT.
6. Remove the 2 screws (gold, tapped, 10mm) securing the COVER ASSY
FRONT IN to the CHUTE ASSY OUT (PL7.1.1).
7. Release the 2 hooks securing the COVER ASSY FRONT IN to the CHUTE
ASSY OUT, and remove the COVER ASSY FRONT IN.
It is better to Spread the SPRING PLATE LINK by using the
C H E C K
P O I N T
small screwdriver.
Disassembly and Assembly
Figure 4-18. COVER ASSY FRONT IN (PL1.2.10) Removal