4.2.16.4 PWB ASSY EARTH (PL13.1.17) Removal
1. Remove the CHUTE ASSY REGI. (See Section 4.2.13.1.)
2. Remove the HOUSING ASSY RETARD. (See Section 4.2.8.1.)
3. Remove the 2 screws (gold, 10mm and gold, tapped, 10mm) and remove
the PLATE EARTH FRONT (PL13. 1. 16).
4. Remove 1 screw (gold, tapped, 10mm) securing the PWB ASSY EARTH
and the PLATE EARTH DIODE (PL13. 1.15) and remove the PWB ASSY
EARTH by floating the PLATE EARTH DIODE.
If the HOUSING ASSY RETARD will not go in easily, pull it to
the left side a little and let it fall in.