Epson AcuLaser C4000 Service Manual page 399

Color laser page printer
Hide thumbs Also See for AcuLaser C4000:
Table of Contents

Advertisement

EPSON AcuLaser C4000/C4100/C3000
4.2.13.2 SENSOR REGI (PL10.1.20) Removal
1. Remove the CHUTE ASSY REGI. (See Section 4.2.13.1.)
2. Remove the ACTUATOR REGI. (See Section 4.2.13.3.)
3. Disconnect the connector (P/J181) on the SENSOR REGI.
4. Release the 3 hooks securing the SENSOR REGI to the CHUTE ASSY
REGI.
5. Remove the SENSOR REGI from the CHUTE ASSY REGI.
Figure 4-81. SENSOR REGI (PL10.1.20) Removal
Disassembly and Assembly
HANABI_BE_CHAP03_054FB
Disassembly Assembly Procedures
4.2.13.3 ACTUATOR REGI (PL10.1.21) Removal
1. Remove the CHUTE ASSY REGI. (See Section 4.2.13.1.)
2. Grasp the screen of the ACTUATOR REGI, let the ACTUATOR REGI shift
to the left side, then remove the right side shaft of the ACTUATOR REGI
from the shaft socket on the CHUTE ASSY REGI.
3. Pull out the ACTUATOR REGI along with the SPRING SENSOR REGI
(PL10.1.22) from the CHUTE ASSY REGI.
4. Remove the SPRING SENSOR REGI from the ACTUATOR REGI.
Figure 4-82. ACTUATOR REGI (PL10.1.21) Removal
Revision F
4-384