IBM F80 Service Manual page 132

Eserver pseries 620 rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 5. SPCN Error Codes (continued)
Error Code
1011 2611
1011 2612
1011 2613
1011 3100
1011 3101
1011 3105
1011 3106
1011 3110
1011 3111
1011 3113
1011 3114
1011 3115
1011 3116
1011 3118
1011 3119
1011 311A
1011 311C
1011 7610
1011 7611
1011 7620
1011 7621
1011 7630
114
Service Guide
Description
Regulator
SPCN Problem
Power configuration fault
I2C controller fault
I2C bus 1 fault
I2C bus 5 fault
I2C bus 6 fault
DASD backplane 1
DASD backplane 2
RIO bus adapter
PCI backplane fault
Operator panel fault
Fan controller fault
SPCN problem
DASD backplane 1
DASD backplane 2
Thermal sensor
Fan 1 failure
Missing fan 1
Fan 2 failure
Missing fan 2
Fan 3 failure
Action/ Possible Failing FRU
1. Processor card
Location: P1-C1
2. System board
Location: P1
System board, Location: P1
220V ac required
System board, Location: P1
1. Operator panel
Location: L1
2. System board
Location: P1
System board, Location: P1
System board, Location: P1
DASD cage 1, Location: B1
DASD cage 2, Location: B2
System board, Location: P1
System board, Location: P1
Operator panel, Location: L1
System board, Location: P1
System board, Location: P1
DASD cage 1, Location: B1
DASD cage 2, Location: B2
1. Operator panel
Location: L1
2. System board
Location: P1
1. Fan 1
Location: F1
2. System board
Location: P1
Fan 1, Location: F1
1. Fan 2
Location: F2
2. System board
Location: P1
Fan 2, Location: F2
1. Fan 3
Location: F3
2. System board
Location: P1

Advertisement