IBM F80 Service Manual page 453

Eserver pseries 620 rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 12. Service Request Numbers (continued)
SRN
FRU List
60210
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
60240
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
6-pack assembly (See "Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays" on page 358.)
7 xxxx
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
6-pack assembly (See "Removing
Six-Position SCSI (SES) or SSA Disk
Drive Bays" on page 358.)
D0000
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
D0100
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
D0101
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
D0200
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
D0300
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
D0400
Disk drive module (See "Removing
Hot-Plug SSA Disk Drives" on
page 324.)
%
Problem
100
Description: The disk drive module failed the
diagnostic test.
Action: Exchange the FRU for a new FRU.
98
Description: A configuration problem has
occurred. A device cannot be configured, for
some unknown reason.
2
Action:
1. Replace the disk drive module. If more than
one DASD is suspect, replace it with its
amber check light either blinking or steady.
2. If the problem remains, replace the 6-pack
assembly.
80
Description: A Service Processor module is
missing from the expected configuration of the
SSA loop.
20
Action: Replace the FRUs one at a time. Go to
"MAP 410: Repair Checkout" in to verify each
repair.
100
Description: The using system cannot configure
the disk drive module. This is probably a software
problem.
Action:
1. Try again to configure the disk drive module.
2. If the problem remains, go to "Software and
Microcode Errors" on page 428 before
exchanging the FRU.
100
Description: Unable to clear a disk drive module
reservation.
Action: Exchange the FRU for a new FRU.
100
Description: The disk drive module has been
reserved since the diagnostics started. The disk
drive module is in use.
Action: Release the disk drive module, and run
the diagnostics again.
100
Description: The disk drive module timed out
while the diagnostics were running.
Action: Rerun the diagnostics. If the problem
remains, exchange the FRU for a new FRU.
100
Description: The disk drive module failed the
diagnostic test. Action: Exchange the FRU for a
new FRU.
100
Description: The disk drive module is not ready
while the diagnostics are running.
Action: Rerun the diagnostics. If the problem
remains, exchange the FRU for a new FRU.
Appendix F. SSA Software and Microcode Errors
435

Advertisement

Table of Contents
loading

This manual is also suitable for:

6f16f0

Table of Contents