down into the socket.
Note: Be sure to reset the time and date and other system options that might have
2. Install the memory riser cards or blank memory cards removed earlier. See
"Removing a Memory Riser Card or One-Way Processor Card" on page 342.
3. Replace the processor and memory card cover.
4. Replace the covers as described in "Replacing Covers" on page 314.

Operator Panel

Removal

Attention:
"Handling Static-Sensitive Devices" on page 310).
Attention:
and time, and service processor call-in functions will be lost. These settings can be
reset after the cable is replaced.
1. Power off the system (see "Powering Off the System" on page 9).
2. Disconnect the ac power cord.
3. Remove the media panel cover to access the operator panel (see "Covers" on
page 311).
been lost when the battery was removed.
If you are running AIX, you might have to run the bootlist command from
AIX while you are logged in as root user. This action restores the customized
boot list. In addition, the IP parameters might also have to be re-entered.
The operator panel card is sensitive to electrostatic discharge (see
If the operator panel cable is disconnected, settings for passwords, date
Chapter 9. Removal and Replacement Procedures