IBM F80 Service Manual page 117

Eserver pseries 620 rs/6000 enterprise server
Hide thumbs Also See for F80:
Table of Contents

Advertisement

Table 2. Firmware Checkpoints (continued)
Checkpoint
Description
E51y (E511 - E5FF)
Configure remote I/O subsystem
Where y is not equal
components
to 0.
E600
SSA PCI adapter open firmware
has run successfully.
E601
SSA PCI adapter BIST has started
but failed to complete after four
seconds.
E602
SSA PCI adapter open firmware
has started.
E603
SSA PCI adapter BIST has
completed with an error.
Action/ Possible Failing FRU
The E51y (E511 to E5FF) codes
are reserved for activities relating
to configuration or testing of the I/O
subsystem, or remote I/O
subsystem. A hang at one of these
codes implies that a severe error
occurred during the programming
of I/O subsystem registers or when
interacting with adapters plugged
into the system. The last two digits
in the checkpoint can be used to
help isolate the location of the I/O
activity that caused the problem.
"y" indicates the PCI bus
occurrence.
If y=_, then the PCI bus is:
Y = PCI bus
1 = 0
2 = 1
See "AIX and Physical Location
Code Tables" in Chapter 1, for
location codes.
Using the information above, go to
"MAP 1540: Minimum
Configuration" on page 57.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
"Determining Location Code" on
page 105.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
"Determining Location Code" on
page 105.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
"Determining Location Code" on
page 105.
If a location code is associated with
the checkpoint, replace the adapter
identified by the location code. See
"Determining Location Code" on
page 105.
Chapter 4. Checkpoints
99

Advertisement

Table of Contents
loading

This manual is also suitable for:

6f16f0