Table 7. Service Processor Error Codes (continued)
Error Code
Description
450E 24A1
Memory system and scan control
routines detected 1W 2M 450 MHz
processor fault
450E 24A2
Memory system and scan control
routines detected 2W 450 MHz
processor fault
450E 24A3
Memory system and scan control
routines detected 4W 450 MHz
processor fault
450E 24A4
Memory system and scan control
routines detected 6W 500 MHz
processor fault
450E 25B6
Memory system and scan control
routines detected 650W power supply
fault
450E 25BB
Memory system and scan control
routines detected 1W 600 MHz
processor fault
450E 25BD
Memory system and scan control
routines detected 2W 600 MHz
processor fault
450E 25BE
Memory system and scan control
routines detected 4W 600 MHz
processor fault
450E 25BF
Memory system and scan control
routines detected 6W 668 MHz
processor fault
450E 25CB
1W processor card fault
450E 25EA
4W processor card fault
450E 25EB
2W processor card fault
450E 25F2
6W processor card fault
450E 263D
Memory system and scan control
routines detected memory filler fault
450E 281F
Memory system and scan control
routines detected SSA backplane
fault
450E 282E
Memory system and scan control
routines detected system board fault
450E 283F
Memory system and scan control
routines detected SCSI backplane
fault
Action/ Possible Failing FRU
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply, Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
Chapter 5. Error Code to FRU Index