Table 6. Firmware Error Codes (continued)
Error Code
Description
21F2 0004
SCSI read/write optical - send
diagnostic failed - DevOfl cmd
2200 0001
PCI Ethernet BNC/RJ-45 or PCI
Ethernet AUI/RJ-45 adapter internal
wrap test failure
2200 1001
10/100 Mbps Ethernet PCI adapter
internal wrap test failure
2201 0001
PCI Auto LANstreamer token ring
adapter failed to complete hardware
initialization.
2201 1001
PCI token ring adapter failed to
complete hardware initialization.
25A0 0001
Cache L2 controller failure
25A1 0001
Cache L2 SRAM failure
Action/ Possible Failing FRU
Before replacing any system
components, refer to the notes in
error code 21A0 0001. Replace the
SCSI device.
Replace the adapter. See
"Determining Location Code" on
page 105 for location code
information related to this error. See
"Replacing the Network Adapter" on
page 105 for adapter information
related to this error.
Replace the adapter. See
"Determining Location Code" on
page 105 for location code
information related to this error. See
"Replacing the Network Adapter" on
page 105 for adapter information
related to this error.
Replace the adapter. See
"Determining Location Code" on
page 105 for location code
information related to this error. See
"Replacing the Network Adapter" on
page 105 for adapter information
related to this error.
Replace the adapter. See
"Determining Location Code" on
page 105 for location code
information related to this error. See
"Replacing the Network Adapter" on
page 105 for adapter information
related to this error.
1. Replace the processor card.
Location: P1-C1
2. Replace the system board. (See
note 3 on page 41.) Location: P1.
Replace the processor card.
Location: P1-C1
Chapter 5. Error Code to FRU Index