Table 7. Service Processor Error Codes (continued)
Error Code
Description
4608 25B6
I/O system and other bus processor
runtime diagnostics detected 650W
power supply fault
4608 25BB
I/O system and other bus processor
runtime diagnostics detected 1W 600
MHz processor fault
4608 25BD
I/O system and other bus processor
runtime diagnostics detected 2W 600
MHz processor fault
4608 25BE
I/O system and other bus processor
runtime diagnostics detected 4W 600
MHz processor fault
4608 25BF
I/O system and other bus processor
runtime diagnostics detected 6W 668
MHz processor fault
4608 263D
I/O system and other bus processor
runtime diagnostics detected memory
filler fault
4608 281F
I/O system and other bus processor
runtime diagnostics detected SSA
backplane fault
4608 282E
I/O system and other bus processor
runtime diagnostics detected system
board fault
4608 283F
I/O system and other bus processor
runtime diagnostics detected SCSI
backplane fault
4608 288D
I/O system and other bus processor
runtime diagnostics detected memory
riser fault
4608 2A00
I/O system and other bus processor
runtime diagnostics detected 6W 4M
500 MHz processor fault
4608 300A
I/O system and other bus processor
runtime diagnostics detected 32MB
DIMM fault
4608 300B
I/O system and other bus processor
runtime diagnostics detected 128MB
DIMM fault
4608 300C
I/O system and other bus processor
runtime diagnostics detected 256MB
DIMM fault
4608 300D
I/O system and other bus processor
runtime diagnostics detected 512MB
(stacked) DIMM fault
Action/ Possible Failing FRU
Power supply, Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
Memory riser card, Location: P1-M1
or P1-M2
Processor card, Location: P1-C1
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Chapter 5. Error Code to FRU Index