Table 7. Service Processor Error Codes (continued)
Error Code
Description
450D 248A
Memory system and attention handler
detected operator panel fault
450D 24A1
Memory system and attention handler
detected 1W 2M 450 MHz processor
fault
450D 24A2
Memory system and attention handler
detected 2W 450 MHz processor
fault
450D 24A3
Memory system and attention handler
detected 4W 450 MHz processor
fault
450D 24A4
Memory system and attention handler
detected 6W 500 MHz processor
fault
450D 25B6
Memory system and attention handler
detected 650W power supply fault
450D 25BB
Memory system and attention handler
detected 1W 600 MHz processor
fault
450D 25BD
Memory system and attention handler
detected 2W 600 MHz processor
fault
450D 25BE
Memory system and attention handler
detected 4W 600 MHz processor
fault
450D 25BF
Memory system and attention handler
detected 6W 668 MHz processor
fault
450D 25CB
1W processor card fault
450D 25EA
4W processor card fault
450D 25EB
2W processor card fault
450D 25F2
6W processor card fault
450D 263D
Memory system and attention handler
detected memory filler fault
450D 281F
Memory system and attention handler
detected SSA backplane fault
450D 282E
Memory system and attention handler
detected system board fault
450D 283F
Memory system and attention handler
detected SCSI backplane fault
Action/ Possible Failing FRU
Operator panel, Location : L1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Replace the processor card,
Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
Chapter 5. Error Code to FRU Index