Table 7. Service Processor Error Codes (continued)
Error Code
Description
460B 24A1
I/O system and wire test detected 1W
2M 450 MHz processor fault
460B 24A2
I/O system and wire test detected 2W
450 MHz processor fault
460B 24A3
I/O system and wire test detected 4W
450 MHz processor fault
460B 24A4
I/O system and wire test detected 6W
500 MHz processor fault
460B 25B6
I/O system and wire test detected
650W power supply fault
460B 25BB
I/O system and wire test detected 1W
600 MHz processor fault
460B 25BD
I/O system and wire test detected 2W
600 MHz processor fault
460B 25BE
I/O system and wire test detected 4W
600 MHz processor fault
460B 25BF
I/O system and wire test detected 6W
668 MHz processor fault
460B 263D
I/O system and wire test detected
memory filler fault
460B 281F
I/O system and wire test detected
SSA backplane fault
460B 282E
I/O system and wire test detected
system board fault
460B 283F
I/O system and wire test detected
SCSI backplane fault
460B 288D
I/O system and wire test detected
memory riser fault
460B 2A00
I/O system and wire test detected 6W
4M 500 MHz processor fault
460B 300A
I/O system and wire test detected
32MB DIMM fault
460B 300B
I/O system and wire test detected
128MB DIMM fault
460B 300C
I/O system and wire test detected
256MB DIMM fault
460B 300D
I/O system and wire test detected
512MB (stacked) DIMM fault
460B 300E
I/O system and wire test detected
512MB (unstacked) DIMM fault
460B 301F
I/O system and wire test detected
128MB DIMM fault
Action/ Possible Failing FRU
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Power supply Location: V1 or V2 or
V3
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Processor card, Location: P1-C1
Memory filler card, Location: P1-M1
or P1-M2
SSA 6-pack, Location: B1 or B2
1. System board, Location: P1
2. Processor card, Location: P1-C1
SCSI 6-pack, Location: B1 or B2
Memory riser card, Location: P1-M1
or P1-M2
Processor card, Location: P1-C1
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Memory DIMM, Location: P1-M1.n or
P1-M2.n or P1-C1-Mn
Chapter 5. Error Code to FRU Index