Step 1540-21
Does the system have adapters or devices that require supplemental media?
NO
YES
Step 1540-22
Consult the PCI adapter configuration documentation for your operating system to verify
that all installed adapters are configured correctly.
Go to "MAP 410: Repair Checkout" in RS/6000 and Eserver pSeries Diagnostic
Information for Multiple Bus Systems .
If the symptom did not change and all the FRUs have been exchanged, call your
service support person for assistance.
Step 1540-23
1. Select Task Selection.
2. Select Process Supplemental Media and follow the on-screen instructions to
process the media.
3. Supplemental media must be loaded and processed one at a time.
Did the system return to the TASKS SELECTION SCREEN after the supplemental
media was processed?
NO
YES
Step 1540-24
The Adapter or device is probably defective.
v If the supplemental media is for an adapter, replace the FRUs in the following order:
1. Adapter
2. System board (see note 3 on page 41)
v If the supplemental media is for a device, replace the FRUs in the following order:
72
Service Guide
Repeat this step until all the FRUs associated with the SRN have been
exchanged or diagnostics has run with no trouble found. Run diagnostics after
each FRU is exchanged.
If the system board or a network adapter is replaced, see note 3 on page 41.
Go to "MAP 410: Repair Checkout" in RS/6000 and Eserver pSeries
Diagnostic Information for Multiple Bus Systems .
If the symptom did not change and all the FRUs have been exchanged, call
your service support person for assistance.
Go to "Step 1540-22".
Press the number 3 key to return to the FUNCTION SELECTION screen.
Go to "Step 1540-23".
Go to "Step 1540-24".
Press "F3" to return to the FUNCTION SELECTION screen.
Go to "Step 1540-19" on page 71.