Table 6. Firmware Error Codes (continued)
Error Code
Description
2602 0007
Failed to allocate bus resources to
PCI adapter
2680 0A0y
MX-PCI bridge BIST failure
2680 0Cxx
Machine check occurred
2803 0xxx
Real time clock (RTC) errors
Action/ Possible Failing FRU
1. Move adapter to another slot
(behind a different PCI bus).
2. Check for available firmware
updates for adapter. Apply update
if available.
3. Run AIX diagnostics on adapter.
Replace if indicated.
4. Replace adapter. See "Replacing
the Network Adapter" on
page 105 for adapter information
related to this error.
5. Check for system firmware
updates. Apply if update
available.
6. Replace system board. (See note
3 on page 41.) Location: P1
The problem is associated with
bridge "y."
Replace the system board. (See note
3 on page 41.)
Location: P1
1. Replace the part identified by the
location code associated with this
error code.
2. If the location code associated
with this error code identifies an
adapter, replace it. See
"Replacing the Network Adapter"
on page 105 for adapter
information related to this error. If
replacing the adapter does not
correct the problem, replace the
system board. (See note 3 on
page 41.) Location: P1
See "Determining Location Code" on
page 105 for location code
information related to this error.
Chapter 5. Error Code to FRU Index