DESCRIPTION OF OPERATOR CONTROLS AND INDICATORS

INTRODUCTION
Major controls and indicators for the CK consist of those for the generator, electrical power
selection and control, lighting, MBUs, hand sink assembly, and cook center ventilation. Other
miscellaneous controls include those for the mobile warming cabinet, refrigerators, oven fan,
tray pack heater fan, and the environmental control unit (ECU).
GENERATOR
The generator control panel is located behind an access door on the food preparation side wall
of the mechanical room. A detailed description of the generator's controls and indicators is
provided in TM 9-6115-642-10.
ELECTRICAL POWER CONTROL AND LIGHTING
Power Entrance Panel
The Power Entrance Panel (PEP), Figure 1, is located on the left mechanical room wall, just
inside the left door. The power cable from the external source is plugged into the connection on
the PEP.
The ground terminal provides a connection for the grounding rod cable when
energizing the CK from the generator. Push button circuit breakers for generator, external
power, and emergency stop circuit control power are located on the side of the panel. These
breakers pop out when tripped, and are pushed in to reset.
EXTERNAL
POWER
CONNECTION
TM 10-7360-226-13&P
Figure 1. Power Entrance Panel.
0005 00-1
CONTROL POW ER
CIRCUIT BREAKERS
GROUND TERMINAL
0005 00