TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK)
0019 00
UNIT MAINTENANCE PROCEDURES
the problem. Remove the power connector at the MBU and check for 24 VDC. If voltage is
present, recheck the procedures in the MBU manual. If 24 VDC is not present, remove the
access cover on the 24 VDC elbow under the cook center and check voltage. If voltage is
present, repair the cable using the repair procedure in the next section. If voltage is not present
refer to the test procedure in WP 0018 00.
REPLACE
Fuel Line: If the fuel line is inoperable because of a damaged connector or a cut or hole in the
hose, replace the entire section of fuel line assembly by disconnecting the hose assembly and
installing a replacement. See Figure 1. Remove and replace the tie-wraps as required.
FUEL LINE
COOK CENTER
Figure 1. Cook Center Fuel Lines.
REPAIR
MBU Cable Assembly:
Make sure the MBU Converter Circuit Breaker #11 on the Power
Distribution Panel is turned OFF. To replace a damaged connector, disassemble the connector
shell.
Label and disconnect the two wires.
Attach the wires to the new connector and
reassemble the shell.
To repair a damaged cable, remove the cover of the junction box under the cook center,
disconnect the wire nuts and pull the cable through the junction box and up through the cook
center frame (see Figure 2). Cut a new cable to the desired length (WP 0045 00, Item 1) and
0019 00-2