TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK)
0021 00
UNIT MAINTENANCE PROCEDURES
Door Seal: Refer to Figure 2. Remove and retain the five door seal mounting screws and the
door seal retaining strip. Install the new door seal using retained hardware.
SEAL, DOOR
GASKET, DOOR
HM15LW
ON
Metro
POWER
MODULE (SEE FIGURE 3)
Figure 2. Mobile Warming Cabinet Maintenance.
Module
The module (Figure 3) is removed from the cabinet using the following procedure:
Make sure the power cord is unplugged and that the module has cooled to a temperature safe
for handling.
Open the bottom door. Remove the module by lifting the front enough to clear the detent, then
pull the module from the cabinet. The power cord should slip through the clearance hole in the
back of the cabinet.
Unfasten the electrical cover by removing the screws along the front bottom of the module and
the top panel. Remove the water pan from the top cover. Open the module by lifting the unit
from the chassis. Turn the unit over for access to the components.
0021 00-3
Need help?
Do you have a question about the IC-M71 and is the answer not in the manual?