OPTIONAL FAN INSTALLATION

NOTE: Illustrations shown without millivolt
board for clarity purposes only.
1. Insert fan through the lower grill opening on left side of gas
valve. Align mounting slots in the fan bracket onto the
mounting studs located at the fireplace rear. Secure
with nuts.
2.
From inside the lower right grill opening, loosen screw
securing the removable access panel (with electrical box &
ro mex
co nnector
3.
Insert 115V wiring (with ground) through romex connector
and wire to the speed control / receptacle assembly matching
the black (hot) white (neutral) and green (ground) wires to
the corresponding wires on the speed control / receptacle
assembly.
NOTE: Speed control / receptacle assembly &
(3) wire nuts are included in the fireplace
components packet.
4. Secure speed control / receptacle assembly to the electrical
box with the (2) screws provided.
5.
Re-install electrical access panel. Tighten screw.
6.
Attach the temperature control switch to the bottom of
firebox.
7. Plug cord into the electrical box receptacle.
8.
Turn speed control counter-clockwise until it „clicks‟. This
is the „OFF‟ position.
9.
Turn speed control „ON‟ by turning the knob clockwise past
the „click‟ - this is the highest setting.
10. Re-install glass assembly.
11. Re-install lower grill, upper louver & upper hood. Refer to
page 42 of this installation manual if necessary.
NOTE: This appliance must be electrically grounded
and connected in accordance with local codes, or in
the absence of local codes, with the National Electrical
Code, ANSI/NFPA 70 Current Edition, or the
Canadian electrical Code CSA C22.1.
NOTE: This fan will not operate unless the speed
control has been turned „ON‟ and sufficient heat has
been applied to the temperature control switch. The
fan will turn „ON‟ and „OFF‟ automatically as the
fireplace heats and cools. Adjust fan to desired speed
while it is running.
installed ).
Re mo ve
p anel.
Temperature Control Switch (Looking through lower grill opening).
TEMPERATURE CONTROL SWITCH POSITION
Before adjusting the temperature control switch, unplug
the 3-prong plug on the fan cord from the receptacle.
Adjust position of the temperature control switch to a
warmer location under the firebox to turn fan „ON‟ sooner
or move it to a cooler location under firebox to turn the fan
„ON‟ later. The fan will turn on when the sensor in the
temperature control switch reaches 110° F and will turn
„OFF‟ when the sensor reaches 90° F. After adjustment,
plug the 3-prong plug on fan cord into the receptacle.