D) FAN INSTALLATION (OPTIONAL)
INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER.
IMPORTANT:
IF THE FAN IS INSTALLED AFTER THE FIREPLACE INSTALLATION, THE LOWER GRILL
MUST BE REMOVED TO PROPERLY INSTALL.
NOTE: If a fan is going to be installed, the wiring must be done prior to enclosing the sides of the fireplace.
An electrical box & romex connector are pre-installed on a removable panel on the left side of the fireplace.
A receptacle / speed control assembly and wire nuts are included in the fireplace components packet.
Your optional fan kit includes:
1.
Right and left fan assemblies with temperature control switch already mounted.
2.
Components package:
NOTE:
To wall-mount the speed control, you will need to purchase a speed control assembly and mounting plate, an electrical
box to mount the speed control and a cover / switch plate with screws.
IMPORTANT:
CODE APPROVED LINE VOLTAGE WIRING 14 GAUGE OR BETTER MUST BE USED
WHEN WIRING THIS SYSTEM. REFER TO YOUR LOCAL ELECTRICAL CODES FOR
SPECIFIC REQUIREMENTS IN YOUR AREA.
WARNING: This appliance is equipped with a three-prong (grounding) plug for protection against shock hazard
and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug.
(4) nuts, installation instructions.