Termination Chart - kozy heat DASSEL DSL-36 Installation And Operation Manual

Direct vent dassel
Table of Contents

Advertisement

NOTE: Pages 27- 28
have information on
restrictor installation
in conjunction with
venting installation.
Page 49 has information on
Restrictor recommendations
depending on burner flame
appearance and instructions on
installation after venting is
completed.
NOTE: Horizontal
sections require
1/4" (6 mm) rise for
every 12" (305 mm)
of travel.
CAUTION: This gas
appliance must not be
connected to or joined
with any other chimney
flue serving another
appliance.
Depending on your
particular venting
needs, a Decreaser
may be necessary to
terminate the venting
system.
For each additional elbow used after the first elbow, 3 ft. (91
each 45° elbow used, 1-1/2 ft. (457 mm) must be subtracted from the maximum venting allowed.
NOTE: (2) 45° degree elbows may be used in place of (1) 90° elbow.
IMPORTANT: A WALL THIMBLE PASS-THRU MUST BE USED ON ALL HORIZONTAL VENT
RUNS THAT PASS THROUGH EITHER INTERIOR OR EXTERIOR WALLS.
IF USING 5" x 8" VENTING, USE KOZY HEAT WALL THIMBLE PASS-THRU (#800-WPT)
FOLLOW INSTRUCTIONS ON PAGE 22 OF THIS INSTALLATION MANUAL.
IF USING A 8" x 6-5/8" DECREASER, FOLLOW VENT PIPE MANUFACTURER‟S
INSTALLATION INSTRUCTIONS FOR THEIR WALL THIMBLE.
IMPORTANT: THE HORIZONTAL VENT HEAT SHIELD INCLUDED WITH THIS FIREPLACE
MUST BE INSTALLED WHEN USING A 90° ELBOW DIRECTLY OFF THE UNIT TO
HORIZONTALLY POSITION THE VENT SYSTEM. THIS INCLUDES ANY CORNER
INSTALLATION.
VENTING
4 mm) must be subtracted from the maximum venting allowed. For
PAGE 31
(Horizontal & Vertical Combination)
TERMINATION MUST BE
WITHIN SHADED AREA.
HORIZONTAL / VERTICAL
COMBINATION
20‟ (6.10 m) VERTICAL
20‟ (6.10 m) HORIZONTAL