INSTALLATION OF THIS FAN SHOULD BE DONE ONLY BY A QUALIFIED INSTALLER
WARNING: MAKE SURE HOUSEHOLD BREAKER IS SHUT OFF PRIOR TO WORKING ON ANY ELECTRICAL LINES.
IMPORTANT: Wiring must be done before enclosing fireplace sides. An electrical box and romex connector are pre-installed on a removable
panel on the right side of fireplace. A receptacle / speed control assembly and (3) wire nuts are included in the fireplace components packet.
The optional fan kit includes:
(2) 110 CFM fan with temperature control switch and 4 ft. (1219 mm) fan cord
(4) 1/4" nuts
NOTE: Code approved line voltage wiring 14 gauge or better must be used when wiring this assembly. Refer local electrical codes for specific
requirements.
WARNING: THIS APPLIANCE IS EQUIPPED WITH A THREE-PRONG (GROUNDING) PLUG FOR PROTECTION AGAINST SHOCK
HAZARD AND SHOULD BE PLUGGED DIRECTLY INTO A PROPERLY GROUNDED THREE-PRONG RECEPTACLE. DO NOT CUT
OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
NOTE: Fan Shields, Speed control / receptacle assembly & (3)
wire nuts are included in the fireplace components packet.
110V - 120V
Incoming wiring
110V - 120V
60Hz

FAN SHIELD INSTALLATION

Two fan shields are included in the fireplace components packet. These shields divert more air circulating through the fans upward,
which increases volume exiting through the upper grill. Install shields onto fans before installing fans in fireplace.
Slide one corner of a fan shield onto the front chute on each fan,
making sure 'V' portion of shield is inside chute.

OPTIONAL FAN INSTALLATION

Electrical Box
Speed Control /
Temperature Switch:
Magnetically attaches to bottom of
firebox.
Receptacle Assembly
Slide fan shield down onto the chute.
PAGE 15