HORIZONTAL TERMINATIONS
90° ELBOW
8" x 6-5/8" DECREASER
IMPORTANT:
Depending on your
particular venting
needs, a Decreaser
may be necessary to
terminate the venting
system.
90° ELBOW
2 FT
(610 mm)
VENTING
(152 mm)
(610 mm)
MAXIMUM HORIZONTAL VENTING
25 ft. (7.62 m) maximum, or 30 ft (9.14 m) maximum when
using stainless steel pipe for the entire length of termination.
8" x 6-5/8" DECREASER
NOTE: Horizontal sections
require 1/4" (6 mm) rise for
every 12" (305 mm) of travel.
(Horizontal)
MINIMUM HORIZONTAL VENTING
WITH 8" x 6-5/8" DECREASER
6"
TERMINATION CAP
2 FT
IMPORTANT: A WALL THIMBLE PASS-THRU
MUST BE USED ON ALL HORIZONTAL VENT
RUNS.
FOLLOW VENT PIPE MANUFACTURER‟S
INSTALLATION INSTRUCTIONS FOR THEIR
WALL THIMBLE.
MAXIMUM HORIZONTAL VENTING
WITH 8" x 6-5/8" DECREASER
PAGE 26
CAUTION: This gas
appliance must not be
connected to or joined with
any other chimney flue
serving another appliance.
IF USING A 8" x 6-5/8" DECREASER
TERMINATION CAP
NOTE: Pages 27-28 have information
on restrictor installation in
conjunction with venting installation.
Page 49 has information on restrictor
recommendations depending on
burner flame appearance and
instructions on installation after
venting is completed.